LORDERAN Constant Temperature Incubator, Precision Laboratory Benchtop Microbial Culture Chamber, RT+5°C to 85°C
- SKU
- H88BKD
- Availability
- In stock
- Questions
LORDERAN · H-BK SERIES
Steady conditions.
Clearer observations.
Bring controlled warmth to everyday laboratory incubation. The H-BK series combines a stainless steel chamber, touch-screen operation and two adjustable shelves in four capacities from 88 to 270 L. Set temperatures from room temperature plus 5 °C to 85 °C, then choose the door design and electrical configuration that fit your work.
Which temperatures?
From 5 °C above room temperature to 85 °C, ±0.5 °C stability at 37 °C. It heats only; it does not cool.
D or G door?
D type has an inner glass door; G type has a viewing window in the outer door.
Which capacity?
88, 160, 200 or 270 L, with two adjustable shelves included.
Which power does it need?
AC 220 V as standard; 110 V, 60 Hz is an option.
H-BK Constant Temperature Incubator datasheet
Full specifications, temperature stability and uniformity, an incubation temperature guide, installation and warranty in one document to share with your team.Download datasheetTHE INCUBATION SEQUENCE
Warm up.
Stabilize. Incubate.
Microcomputer control brings the chamber toward the selected temperature. The 1–9999 minute timer supports scheduled incubation, while the touch screen keeps operation at the front of the instrument.
RT means room temperature. At 25 °C ambient, the specified lower limit is 30 °C. Ambient operating range: 5–30 °C.
Read temperature performance
in two dimensions.
Stability and uniformity describe different parts of the incubation environment. Compare their published values at the stated test temperature.
IN TIME
Temperature stability.
How steady is the temperature during incubation? The published stability and fluctuation values are both stated at 37 °C.
±0.5 °C at 37 °C
ACROSS THE CHAMBER
Temperature uniformity.
How consistent is the chamber environment across positions? Uniformity is specified separately from temperature stability.
±1 °C at 37 °C
Concept illustrations explain the specification categories; they do not show measured sample data.
Choose how you observe.
D and G identify different door designs. Check the door type as well as the capacity when comparing dimensions.
D TYPE
Inner glass door.
A separate glass door sits behind the outer door. The concept illustration shows the outer door open to reveal the inner glass panel.
Listed capacities: 88 L and 160 L
G TYPE
Viewing window.
A window in the outer door provides a view into the chamber. Dimensions for G-type configurations are listed separately below.
Listed capacities: 88, 160, 200 and 270 L
Door concept illustrations are schematic. Select the available configuration using the product options above.
Four capacities. A practical choice.
Compare chamber dimensions and power consumption, then check the external and packing dimensions for the chosen door style.
88 L
345 WPower consumption
Chamber dimensions (mm)500 × 364 × 500
160 L
495 WPower consumption
Chamber dimensions (mm)558 × 518 × 600
200 L
645 WPower consumption
Chamber dimensions (mm)598 × 638 × 548
270 L
645 WPower consumption
Chamber dimensions (mm)665 × 720 × 600
Illustrations show proportional G-type profiles for comparison. Actual dimensions are listed in the specifications.
Start with the sample.
Compare your vessels or trays with the internal dimensions. The four capacities share two adjustable shelves.
Choose the door design.
Select an inner glass door or an outer viewing window, then check the dimensions for that configuration.
Match your laboratory.
Choose the specified 220 V standard configuration or 110 V option, including the correct frequency.
Practical controls.
Essential protection.
Touch-screen operation and a stainless steel chamber are complemented by adjustable loading space and dedicated protection functions.
LED touch screen
A touch-screen interface places the operating controls on the front of the incubator.
Microcomputer controller
Electronic control for the specified incubation temperature and timing settings.
Stainless steel chamber
A stainless steel interior forms the sample chamber.
Two adjustable shelves
Two shelves are included as standard, with adjustable positions.
1–9999 minute timer
A wide timer setting range supports different incubation durations.
Temperature performance
Stability and fluctuation are both specified as ±0.5 °C at 37 °C.
Over-temperature alarm
Alerts when an over-temperature condition occurs.
Independent limit alarm
A separate limit-temperature alarm system is included.
Electrical protection
Leakage-current and over-voltage protection are provided.
Specifications
Models H88BK, H160BK, H200BK and H270BK. Standard 220 V; optional 110 V.
Differs between models
| Model | H88BK | H160BK | H200BK | H270BK |
|---|---|---|---|---|
| Model and dimensions | ||||
| Capacity | 88 L | 160 L | 200 L | 270 L |
| Door configurations listed | D / G type | D / G type | G type | G type |
| Internal size (mm) | 500 × 364 × 500 | 558 × 518 × 600 | 598 × 638 × 548 | 665 × 720 × 600 |
| External size (mm) | D type650 × 573 × 793G type627 × 621 × 692 | D type718 × 732 × 890G type685 × 779 × 790 | G type725 × 809 × 830 | G type791 × 859 × 912 |
| Packing size (mm) | D type720 × 630 × 930G type697 × 671 × 829 | D type788 × 792 × 1027G type755 × 829 × 927 | G type830 × 895 × 990 | G type900 × 945 × 1075 |
| Gross weight (kg) | 65 | 80 | 86 | 100 |
| Performance | ||||
| Temperature range | RT + 5 °C to 85 °C | |||
| Temperature stability | ±0.5 °C at 37 °C | |||
| Temperature fluctuation | ±0.5 °C at 37 °C | |||
| Temperature uniformity | ±1 °C at 37 °C | |||
| Ambient temperature | 5–30 °C; recommended 25 °C ±2 °C | |||
| Temperature control method | PT100 | — | — | — |
| Control and chamber construction | ||||
| Display | LED touch screen | |||
| Controller | Microcomputer controller | |||
| Chamber material | Stainless steel | |||
| Shelves, standard | 2, adjustable | |||
| Time range | 1–9999 min | |||
| Electrical | ||||
| Power consumption | 345 W | 495 W | 645 W | 645 W |
| Standard power supply | AC 220 V ±10%, 50/60 Hz | |||
| Optional power supply | AC 110 V ±10%, 60 Hz | |||
| Safety systems | ||||
| Over-temperature alarm | Included | |||
| Independent limit-temperature alarm | Included | |||
| Leakage-current and over-voltage protection | Included | |||
Dimensions follow the order listed in the original product specification. D and G dimensions are identified separately. D/G styles are listed for 88 L and 160 L; G style is listed for 200 L and 270 L. A dash (—) means the value is not separately specified in the published table.
RT = room temperature. The lower temperature limit is 5 °C above ambient. For example, at 25 °C ambient, the specified lower limit is 30 °C. Stability, fluctuation and uniformity values are stated at 37 °C.
Questions before you order.
A few details to confirm when selecting the capacity, door design and electrical configuration.
What does RT + 5 °C mean?
RT means room temperature. The lower limit is 5 °C above the ambient room temperature, and the upper limit is 85 °C. At 25 °C ambient, the specified range therefore begins at 30 °C.
What is the difference between D type and G type?
D type has an inner glass door. G type has a viewing window in the outer door. Their external and packing dimensions differ for the 88 L and 160 L models; compare the labeled values in the specification table.
Which door styles are listed for each capacity?
The product options list both D and G styles for 88 L and 160 L, and G style for 200 L and 270 L. Choose the capacity, voltage and available door style in the product options above.
Are the shelves included?
Yes. Two adjustable shelves are included as standard.
Which electrical configurations are specified?
The standard supply is AC 220 V ±10%, 50/60 Hz. AC 110 V ±10%, 60 Hz is listed as an option. Select the configuration that matches the laboratory supply.
What does the warranty cover?
A 2-year warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded.
Can I return it?
Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.
How is it delivered, and when does it ship?
Freight, duties and taxes are paid to your loading dock; moving the incubator inside is not included. Your confirmed ship date is included in the order acknowledgement.
Can I get a formal quote for a purchase order?
Yes. Select your model and options, then click Get a quote for a PDF quotation with DDP shipping included.
Choose volume, voltage and door
The price and PDF quote update with your choices.