Lab Shaker

LORDERAN 80L Refrigerated Incubator Shaker, Benchtop, 4-60°C, 30-400 rpm Orbital Shaker for Cell Culture & Microbiology

SKU
200B
Availability
In stock
Questions

Ask about this instrument

LORDERAN 80L Refrigerated Incubator Shaker, Benchtop, 4-60°C, 30-400 rpm Orbital Shaker for Cell Culture & Microbiology

An engineer replies by email or phone, usually within 12 hours.

Power · 110V

Incubation, refrigeration and orbital shaking in one benchtop chamber. The 200B holds 80 L anywhere from 4 °C to 60 °C to ±0.1 °C, while a single balanced shaft turns the platform from 30 to 400 rpm, quietly and without splashing.

80 Lbenchtop chamber
4–60 °Cincubate or refrigerate
±0.5 °Cuniformity
30–400rpm, soft start
Ø 25 mmorbit
4 °C60 °C

The cooler pulls down to 15 °C below room temperature, so 4 °C is reached when the lab is at 19 °C or cooler.

How cold can it go?

To 4 °C when the lab is at 19 °C or cooler: the cooler pulls down to 15 °C below room temperature. It heats to 60 °C.

What fits on the plate?

A 420 × 400 mm shaking plate in an 80 L benchtop chamber; see Plan your plate for flask counts.

How fast does it shake?

30 to 400 rpm on a 25 mm orbit, ±1 rpm, with soft start so flasks do not slosh over.

Which power does it need?

110 V or 220 V. Choose the voltage in the configurator.

TECHNICAL DATASHEET · PDF · 5 PAGES

200B 80 L Refrigerated Incubator Shaker datasheet

Full specifications, capacity planning, motion and temperature performance, installation requirements and warranty in one document to share with your team.
Download datasheet

One balanced shaft, one steady orbit

The platform rides on a single-shaft drive turned by a brushless motor. Soft start ramps up the speed so flasks never slosh over, and the drive needs no routine maintenance.

Every flask traces the same 25 mm circle

30–400rpm speed range
±1 rpmspeed accuracy
Ø 25 mmorbit
420 × 400mm shaking plate
  • Soft start brings the platform up to speed without splashing samples.
  • Single-shaft drive mechanism for quiet operation on the bench.
  • Maintenance-free brushless motor built for long service life.
  • Shaking stops when the cover opens and resumes automatically after a power cut.

Speed and orbit set the mixing

How hard the platform pushes your flasks depends on speed and orbit: the peak acceleration grows with the square of the speed and in proportion to the orbit. At 400 rpm a 25 mm orbit reaches about 2.24 g.

25 mm orbit0 g0.5 g1 g1.5 g2 g2.5 g0100200300400speed, rpm2.24 g25 mm orbit0 g0.5 g1 g1.5 g2 g2.5 g0100200300400speed, rpm2.24 g25 mm orbitup to 400 rpm: 2.24 g peak

Peak acceleration = (2π × rpm / 60)² × orbit radius, in multiples of g (9.81 m/s²). The drawing shows the orbits to scale.

Incubate or refrigerate in the same chamber

A 400 W heater and a 118 W CFC-free cooler work under microprocessor control, with an adjustable circulation fan spreading the air evenly around every flask.

Temperature range

From cold storage to warm incubation

4–60 °C

Control accuracy

±0.1 °C

Set and actual values shown side by side on the LCD.

400 Wheater
118 Wcooler

Uniformity

±0.5 °C

Adjustable circulation fan for even temperature across the plate.

134ACFC-free coolant
580 Wpower

Plan your plate

The 420 × 400 mm shaking plate takes flasks from 50 ml to 2000 ml. Each layout shows the maximum load for one flask size.

2000 ml× 4 maximum

1000 ml× 8 maximum

500 ml× 12 maximum

250 ml× 18 maximum

100 ml× 32 maximum

50 ml× 45 maximum

Layouts are illustrative and show the maximum number of flasks of one size.

Standard configuration

Supplied with every 200B.

3× 500 ml
4× 250 ml
5× 100 ml
5× 50 ml

Made to run unattended

Program a run, close the tempered-glass cover and walk away. The shaker keeps time, watches its own temperature and protects your samples if something changes.

Show all 15 features: Control · Protection · Everyday use

Control

  • Microprocessor control of temperature and shaking speed
  • Programs with repetition, steps and eight curves
  • Timer from 0 to 999 h 59 min, or continuous running
  • LCD shows set and actual values
  • Adjustable circulation fan speed

Protection

  • High and low temperature alarm
  • Shaking stops automatically when the cover opens
  • Run resumes automatically after power is restored
  • Sealed digital panel keeps spilled liquid out
  • Soft start prevents samples from splashing

Everyday use

  • Compact benchtop design with low running noise
  • Tempered glass window to check samples without opening
  • Cover opens wide for easy loading and sample selection
  • User-friendly LCD screen and operation panel
  • Maintenance-free brushless motor

Specifications

200B

Available in 110 V and 220 V versions.

Temperature
Temperature Range 4°C*-60°C(*RT.-15°C)
Accuracy of Temperature ±0.1°C
Temperature Uniformity ±0.5°C
Coolant CFC-Free (134A)
Cooler 118W
Heater 400W
Shaking
Speed Range 30~400rpm
Speed Accuracy ±1rpm
Orbit Dia. 25mm
Programming Function Programming of repetition, steps and eight curves settings
Size of Shaking Plate 420×400 mm
Maximum Capacity 2000ml×4 or 1000ml×8 or 500ml×12 or 250ml×18 or 100ml×32 or 50ml×45
Standard Configuration 500ml×3, 250ml×4, 100ml×5, 50ml×5
Dimensions, weight and power
Size of Chamber 460×500×350 mm
External Size 780×690×600 mm
Net Weight 100kg
Gross Weight 132kg
Power 580W

*The lowest temperature is room temperature (RT) minus 15 °C, with 4 °C as the lowest set point.

Questions buyers ask

Warranty, returns, delivery and quotes.

What does the warranty cover?

A 3-year worldwide warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, belts and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the shaker inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your model and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose your voltage

The price and PDF quote update with your choices.

Configure yours