CO2 Incubator

LORDERAN 90℃ Moist Heat Sterilization CO2 Incubator, Professional Cell Culture Incubator with Infrared IR Sensor

SKU
C80II
Availability
In stock
Questions

Ask about this instrument

LORDERAN 90℃ Moist Heat Sterilization CO2 Incubator, Professional Cell Culture Incubator with Infrared IR Sensor

An engineer replies by email or phone, usually within 12 hours.

Volume · 80L (2.82 Cu. Ft.)
Power · 110V

LORDERAN · C-II SERIES

Precision CO₂ incubation.

Air-jacketed CO₂ incubator with infrared sensing, PT100 temperature control and a dedicated 90 °C moist heat decontamination cycle. Available in 80 L and 160 L.

90 °C moist heatInfrared CO₂ sensorAir jacket + PID
Cell cultureTissue engineeringPharmaceutical researchBiotechnology
LORDERAN TEMPERATURE 37.0 °C CO₂ 5.0 % 90 °C Moist heat cycle 0–20 vol% Infrared CO₂ control
90 °CMoist heat cycle
0–20 vol%CO₂ control range
±0.3 °CFluctuation at 37 °C
80 / 160 LTwo chamber capacities

What is the 90 °C cycle for?

Moist heat decontamination of the chamber. Routine incubation runs from RT + 5 °C to 60 °C.

How is CO₂ measured?

By an infrared sensor: 0–20 vol%, 0.1 vol% resolution, supplied with a calibration certificate.

Is humidity controlled?

It is displayed in real time, with a bottom water reservoir and low-water alarm; an active RH control range is not specified.

What do I need on site?

A CO₂ supply and 110 V or 220 V. Choose 80 L or 160 L in the configurator.

TECHNICAL DATASHEET · PDF · 6 PAGES

C80II / C160II 90 °C Moist Heat CO₂ Incubator datasheet

Full specifications, CO₂ and medium pH reference values, the 90 °C decontamination cycle, installation and warranty in one document to share with your team.
Download datasheet

CULTURE CONTROL

Temperature and
CO₂ control.

PID temperature control uses a PT100 sensor. CO₂ is regulated by a dual-channel, dual-filter infrared sensor supplied with a calibration certificate.

Temperature · relative response CO₂ · relative response TargetTarget ConditioningTime →
01 · Setpoints02 · Response03 · Regulation
Illustrative control responses on relative scales; not measured data.
RT + 5 to 60 °CIncubation temperature range
0.1 vol%CO₂ control resolution
0.2 vol%CO₂ uniformity

RT = room temperature. The lower incubation limit is 5 °C above ambient: 30 °C at a room temperature of 25 °C.

CHAMBER DECONTAMINATION

90 °C moist heat
decontamination.

A dedicated moist heat cycle supports chamber decontamination between culture runs. The 90 °C cycle is separate from routine incubation.

Refer to the model-specific instructions for cycle preparation and compatible accessories.

90 °C60 °C37 °C 90 °C moist heat cycle Incubation reference CultureDecontaminationReturn to culture
Illustrative sequence at a 37 °C incubation reference; no cycle duration is specified.
±0.3 °CTemperature fluctuationAt 37 °C
±0.5 °CTemperature uniformityAt 37 °C
0.1 °CTemperature precision
0–999 hTimer rangeOr continuous operation

Chamber design
and operation.

Humidity monitoring, accessible controls and a cleanable stainless steel interior support routine culture work.

Air-jacket design

Air-jacket construction supports the chamber’s controlled thermal environment.

7-inch touch screen

Touch-screen operation with a 0–999 h timer or continuous running.

Humidity monitoring

Real-time display of chamber humidity during operation.

Water reservoir

Bottom-mounted reservoir with a low-water-level alarm.

304 stainless steel

Electrochemically treated interior with rounded internal corners.

Adjustable shelves

Two adjustable shelves for vessel and tray placement.

Temperature & CO₂ alarms

Over-temperature, under-temperature, high-CO₂ and low-CO₂ alarms.

Water-level monitoring

Low-water-level alarm for the chamber reservoir.

Electrical protection

Leakage-current and over-voltage protection.

80 L or 160 L.

Compare internal dimensions, cabinet footprint and power consumption. Both models share the same control specifications.

80 L

C80II

650 WPower consumption

Internal W × D × H368 × 452 × 517 mm

External W × D × H611 × 773 × 841 mm

Net weight72 kg

160 L

C160II

700 WPower consumption

Internal W × D × H468 × 552 × 648 mm

External W × D × H711 × 873 × 991 mm

Net weight95 kg

Cabinet profiles are drawn to a common scale.

01 · SAMPLE SPACE

Vessel clearance.

Check internal dimensions and shelf positions against your vessels or trays.

02 · ENVIRONMENT

Ambient conditions.

Ambient range: 5–30 °C. Recommended: 25 ±2 °C.

03 · UTILITIES

Power and gas.

Select 110 V or 220 V. Confirm the CO₂ supply and installation requirements.

04 · DECONTAMINATION

Cycle requirements.

Review the moist heat procedure and accessory compatibility for your workflow.

Specifications

C80II and C160II. Select 110 V or 220 V.

Differs between models

Model C80II C160II
Model and dimensions
SKU C80II C160II
Capacity 80 L (2.82 cu ft) 160 L (5.65 cu ft)
Internal size W × D × H (mm) 368 × 452 × 517 mm 468 × 552 × 648 mm
External size W × D × H (mm) 611 × 773 × 841 mm 711 × 873 × 991 mm
Packing size W × D × H (mm) 725 × 887 × 985 mm 820 × 1010 × 1128 mm
Net weight 72 kg 95 kg
Gross weight 93 kg 120 kg
Temperature and decontamination
Type Air jacket
Sterilization type 90 °C moist heat sterilization
Temperature sensor PT100
Temperature range RT+5 to 60 °C
Temperature fluctuation ±0.3 °C (at 37 °C)
Temperature uniformity ±0.5 °C (at 37 °C)
Temperature precision 0.1 °C
CO₂ control
CO₂ sensor IR infrared sensor with calibration certificate
CO₂ range 0–20 vol%
CO₂ uniformity 0.2 vol%
CO₂ control resolution 0.1 vol%
Filter CO₂ gas filter
Sensor technology Dual-channel, dual-filter infrared technology
Controls, chamber and humidity
Display 7-inch touch screen
Timing range 0–999 h or continuous
Shelves 2 pcs, adjustable
Humidity display Real-time humidity display
Water reservoir Bottom-mounted water reservoir
Interior 304 stainless steel, electrochemically treated; semicircular inner corners
Temperature control PID control
Electrical and operating environment
Power consumption 650 W 700 W
Voltage 110 V or 220 V
Ambient temperature 5–30 °C (recommended 25±2 °C)
Accessories and protection
Standard accessories Shelves, USB interface, CO₂ relief valve, CO₂ gas filter
Optional accessories Water pump, three-way connector
Temperature alarms Over-temperature and under-temperature alarms
CO₂ alarms Over-concentration and under-concentration alarms
Water-level alarm Low-water-level alarm
Electrical protection Leakage-current and over-voltage protection

Dimensions: width × depth × height. CO₂ values: volume percent (vol%). Amber markers indicate model-dependent values.

Operating conditions. RT = room temperature. Incubation: RT + 5 °C to 60 °C. Decontamination: 90 °C. Temperature fluctuation and uniformity are specified at 37 °C. Humidity is monitored; an active RH control range is not specified.

Configuration and
accessories.

Select the capacity and voltage above. Optional accessories are specified separately.

Standard equipment

  • Two adjustable shelves
  • USB interface
  • CO₂ relief valve
  • CO₂ gas filter

Optional accessories

  • Water pump
  • Three-way connector

Specify optional items when ordering.

Application and installation support.

Confirm culture conditions, CO₂ supply and cycle compatibility. Request model-specific operating documents before installation.

Contact LORDERAN

Technical questions.

Operating limits and configuration at a glance.

What does RT + 5 °C mean?

RT is room temperature. The lower incubation limit is 5 °C above ambient: 30 °C at a room temperature of 25 °C. The upper limit is 60 °C.

Is 90 °C used during incubation?

90 °C is used for the separate moist heat decontamination cycle. Routine incubation operates at RT + 5 °C to 60 °C.

What do the CO₂ specifications mean?

CO₂ range: 0–20 vol%. Control resolution: 0.1 vol%. Uniformity: 0.2 vol%. The infrared sensor is supplied with a calibration certificate.

Is humidity actively controlled?

Humidity is displayed in real time. A bottom water reservoir and low-water-level alarm are included; an active RH control range is not specified.

What should I confirm before ordering?

Confirm 80 L or 160 L, 110 V or 220 V, installation dimensions and CO₂ supply. Specify the optional water pump or three-way connector if required.

What does the warranty cover?

A 2-year warranty from the date of purchase, covering core components and controls. We repair first; if a major defect can’t be repaired, we replace the unit or give a full refund. Seals, heating tubes and other wear parts are excluded.

Can I return it?

Yes, within 30 days of delivery if unused and in original condition. For non-quality returns the buyer pays return shipping, a 3% restocking fee and the card processing fee. Defective or damaged items are covered in full.

How is it delivered, and when does it ship?

Freight, duties and taxes are paid to your loading dock; moving the incubator inside is not included. Your confirmed ship date is included in the order acknowledgement.

Can I get a formal quote for a purchase order?

Yes. Select your model and options, then click Get a quote for a PDF quotation with DDP shipping included.

Choose volume and voltage

The price and PDF quote update with your choices.

Configure yours