Large Load, Powerful, Reliable
Automatic high-pressure steam sterilization
One-time molded stainless steel structure
Plug & Play Installation
Intelligent temperature control, fast heating
High Sterilization Efficiency
Easy To Replace Parts
Two Years Warranty
Small foot print
LCD display
Leakage breaker
Safety Interlocking
Up to 134℃
Safety valve
Auto-exhaust
Easy setting
Automatic shutdown
Full SS304
Fully automatic
Anti-dry burning
Large load
Cycle Time Counter
Overpressure protection
Elevate Your Sterilization
With its large capacity, rapid cycle times, and advanced safety features.
Constructed from high-quality stainless steel for durability and corrosion resistance.
Whether you're sterilizing medical instruments, laboratory glassware, biological substrate, or industrial components, our autoclave can be meet your specific requirements.
Lid
Bolt type lid structure. Mechanical safety interlocking device.
Display Panel
Microprocessor control system, stable and easy to operate.
Pressure Gauge
The pressure gauge displays the reading in psi/bar.
Exhaust method
Automatic exhaust, safe and worry-free.
Natural cooling available.
Warranty policy
Major defects under warranty, a full refund or a replacement unit.
Sterilization
Automatic cycle sterilization program.Takes 35-40 minutes for the ambient temperature to reach 132℃.
Material
All stainless-steel material. The inner liner is made of extra thick stainless steel, high safety coefficient.
Plug
Come standard with NEMA 10-50P plug. Removable and replaceable.
Lid
Bolt type lid structure. Mechanical safety interlocking device.
Display Panel
Microprocessor control system, stable and easy to operate.
Pressure Gauge
The pressure gauge displays the reading in psi/bar.
Exhaust method
Automatic exhaust, safe and worry-free.
Natural cooling available.
Warranty policy
Major defects under warranty, a full refund or a replacement unit.
Sterilization
Automatic cycle sterilization program.Takes 35-40 minutes for the ambient temperature to reach 132℃.
Material
All stainless-steel material. The inner liner is made of extra thick stainless steel, high safety coefficient.
Plug
Come standard with NEMA 10-50P plug. Removable and replaceable.
250CA
250 Lilters (Φ23.62' x 34.65') / (Φ600 × 880mm)
32psi (0.22mpa)
134℃
105~134℃ (221~273°F)
≤0.5℃
0-9999mins
3 * (Φ550 × 220mm)
Automatic / Natural cooling
Manual drainage
8kw/220v, 37amps, single phase
Three-pronged, NEMA 10-50P (Removable)
28.35' x 28.35' x 58.27' (720×720×1480mm)
485lbs / 419lbs (220Kg / 190Kg)
Step 01
P-1: set it as 102°C-103°C.
When the heating temp. reach 102°C-103°C, the exhaust will close automaticlly. (Default is 102°C)
Step 02
P-2: Set the sterilize temperature. Setting range is 105°C-134°C
Step 03
P-3: Set the sterilize time, Timer range is 0-9999mins.
Step 04 (Optional)
P-4: Set the drying time. (It's optional function, if it's not available in your autoclave, press the SET key to skip.)
Step 05
P-5: It's sterilize mode. Press the SET key to skip, no need to change the mode.
Step 06
P-6: Counting function. This displays the number of times the autoclave has been used.
Step 07* (Optional)
P-7: Multiple exhaust times, exclusive to drying function. Setting at 2 or 3 (Recommend 2).
Temperatures will cycle between 115 and 105 °C 2 or 3 times for a more balanced temperature.
Sterilize Mode*
Exhaust valve*
Automatic exhaust is standard.
Do not operate the exhaust valve manually, keep the exhaust valve closed. (In case of emergency, open it manually for quick venting.)